Showing results: 61 - 75 of 1478 items found.
-
40-837A-102 -
Pickering Interfaces Ltd.
The 40-837A-102 (PXI) and 42-837A-102 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
40-877A-001 -
Pickering Interfaces Ltd.
The 40-877A-001 (PXI) and 42-877A-001 (PXIe) are 50Ω 2x2 RF matrices with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-877A-101 -
Pickering Interfaces Ltd.
The 40-877A-101 (PXI) and 42-877A-101 (PXIe) are 50Ω 2x2 RF matrices with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-877A-001 -
Pickering Interfaces Ltd.
The 40-877A-001 (PXI) and 42-877A-001 (PXIe) are 50Ω 2x2 RF matrices with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-877A-101 -
Pickering Interfaces Ltd.
The 40-877A-101 (PXI) and 42-877A-101 (PXIe) are 50Ω 2x2 RF matrices with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-837A-001 -
Pickering Interfaces Ltd.
The 40-837A-001 (PXI) and 42-837A-001 (PXIe) are 75Ω 2x2 RF matrices with 1 bank in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-877A-102 -
Pickering Interfaces Ltd.
The 40-877A-102 (PXI) and 42-877A-102 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-877A-002 -
Pickering Interfaces Ltd.
The 40-877A-002 (PXI) and 42-877A-002 (PXIe) are 50Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-877A modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
42-837A-102 -
Pickering Interfaces Ltd.
The 40-837A-102 (PXI) and 42-837A-102 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
42-837A-002 -
Pickering Interfaces Ltd.
The 40-837A-002 (PXI) and 42-837A-002 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
778572-40 -
NI
350 MHz, 8x9 PXI RF Matrix Switch Module—The PXI‑2540 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXI‑2540 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers.
-
780587-40 -
NI
PXIe, 350 MHz, 8x9 PXI RF Matrix Switch Module—The PXIe‑2540 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXIe‑2540 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers.
-
40-729-002-L -
Pickering Interfaces Ltd.
40-727/728/729 are RF Matrix Modules suitable for switching frequencies to 300MHz (50Ω version). The modules are available in either 50Ω or 75Ω versions with a choice of coaxial connectors. The 40-727/728/729 are designed designed to provide a simple and scalable bidirectional matrix to RF frequencies. They are intended for the easy construction of high performance bidirectional matrix switching systems.
-
40-727-002-L -
Pickering Interfaces Ltd.
40-727/728/729 are RF Matrix Modules suitable for switching frequencies to 300MHz (50Ω version). The modules are available in either 50Ω or 75Ω versions with a choice of coaxial connectors. The 40-727/728/729 are designed designed to provide a simple and scalable bidirectional matrix to RF frequencies. They are intended for the easy construction of high performance bidirectional matrix switching systems.
-
40-728-002-L -
Pickering Interfaces Ltd.
40-727/728/729 are RF Matrix Modules suitable for switching frequencies to 300MHz (50Ω version). The modules are available in either 50Ω or 75Ω versions with a choice of coaxial connectors. The 40-727/728/729 are designed designed to provide a simple and scalable bidirectional matrix to RF frequencies. They are intended for the easy construction of high performance bidirectional matrix switching systems.